Ground Path of PCB Board Design
A more realistic model of a ground system is shown in Below Figure. The signal return current flows in the complex impedance existing between points G1 & G2 of Ground Path of PCB Board Design as shown, giving rise to a voltage drop ÄV in this path. But it is important to note that additional external currents, such as IEXT, may also flow in this same path. It is critical to Some portion of these undesired voltages may end up being seen at the signal’s load end, and they can have the potential to corrupt the signal being transmitted.
It is evident, of course, that other currents can only flow in the ground impedance, if there is a current path for them. In this case, severe problems can be caused by a high current circuit sharing an unlooped ground return with the signal source.
Below Figure shows just such a common ground path, shared by the signal source and a high current circuit, which draws a large and varying current from its supply. This current flows in the common ground return, causing an error voltage ÄV to be developed.
From Below Figure, it is also evident that if a ground network contains loops, or circular ground conductor patterns (with S1 closed), there is an even greater danger of it being vulnerable to EMFs induced by external magnetic fields. There is also a real danger of ground-current-related signals “escaping” from the high current areas, and causing noise in sensitive circuit regions elsewhere in the system.